External extension module for automation control for SETEBOS devices, HYPERION-105-X-IO1W and HYPERION-30x-3
External extension module for automation control for SETEBOS devices, HYPERION-105-X-IO1W and HYPERION-30x-3
Extension of the number of IO interfaces to SETEBOS, HYPERION-105-X-IO1W and HYPERION-30x-3 devices
Interface nx of digital inputs for transferring short-circuit or open-circuit states
Interface nx low-voltage controlled relay outputs, NO/NC connectors
Voltage measurement 0-60V DC - Interface 1x RS485 or 1-Wire for communication with management device
Operating temperature from -40 to +70°C
Can be mounted on DIN rail TH35
Power supply from the device or external in the range 9-60V DC
| - EN 55022:2010/AC:2011 - Electromagnetic compatibility (EMC) - Information technology equipment. Characteristics | |||||||||||||||
| Radio disturbance characteristics. Methods of measurement and permissible levels | |||||||||||||||
| - PN-EN 55024:2011/A1:2015-08 - Electromagnetic compatibility (EMC) - Information technology equipment - Immunity characteristics. | |||||||||||||||
| Immunity - Limits and methods of measurement. | |||||||||||||||
| - PN-EN 60950-1:2007/A2:2014-05 - Information technology equipment - Safety - Part 1: Requirements. | |||||||||||||||
| Basic requirements, | |||||||||||||||
| - EMC 2004/108/EC - Electromagnetic compatibility directive. | |||||||||||||||
| - LVD 2006/95/EC - Low voltage directive. | |||||||||||||||
| - IEC 61000-4-2 Electromagnetic compatibility (EMC)- Part 4-2: Testing and measurement techniques - Electrostatic | |||||||||||||||
| discharge immunity test | |||||||||||||||
| - IEC 61000-4-3 Electromagnetic compatibility (EMC)- Part 4-3: Testing and measurement techniques - Radiated, radiofrequency, electromagnetic field immunity test | |||||||||||||||
| - IEC 61000-4-4 Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast | |||||||||||||||
| transient/burst immunity test | |||||||||||||||
| - IEC 61000-4-5 Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test | |||||||||||||||
| - IEC 61000-4-6 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to | |||||||||||||||
| conducted disturbances, induced by radio-frequency fields | |||||||||||||||
| - IEC 61000-4-8 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency | |||||||||||||||
| magnetic field immunity test | |||||||||||||||
| *- The scope and list of supported standards may change as the device is developed. | |||||||||||||||
| - Maximum switching voltage 60VDC | ||||
| - Maximum switching current - 0.5A, 48VDC | ||||
| - Connector: crimped screw terminal | ||||
| - Number of inputs - depending on version | |||
| - Galvanically isolated inputs | |||
| - Input type - dry contact | |||
| - Connector: crimped screw terminal | |||
| - Baud rate: 0-230 kbps | |||
| - RS485 interface configuration | |||
| - 2 wire | |||
| - 4 wire | |||
| - Connector: crimped screw terminal | |||
| - Voltage measuring range - 0 ÷ 60V DC | |||||
| - Voltage measurement accuracy - ± 0.25V | |||||
| Number of outputs - depending on version | |||||
| - Type of outputs - "relay contact", NO/NC connectors | |||||
| - Transmission rate 0 - 16.3 kbit/s | |||
| - Range ≤ 100m | |||
| - Connector: screw terminal | |||
| - Voltage ranges: 9 ÷ 60VDC | ||||
| - Connector: 2-pin screw terminal connector | ||||
| - Can be mounted on DIN rail TH35 | |||
| - Dimensions 90x75x50 mm | |||
| - Standard operating temperature: -40÷ +70°C | ||||
| - Standard ambient humidity: ≤ 95% (non | ||||
| condensation) | ||||
- 3 years