Hyperion 500
Industrial Ethernet switch in the 10/100 / 1000M modular system equipped with 8x slots, depending on the housing version, dedicated to the installation of advanced hot-swap modules that enable various configurations of RJ45, SFP connectors, ensuring, among others, transmission in supervision and operation of substations, to provide reliable connections between the SCADA system and network controllers, to create CCTV IP monitoring systems, to support communication on wind farms, to monitor environmental parameters in difficult conditions, to implement intelligent applications in industry.
Modular Managed industrial Ethernet switch with PTPv2 time synchronization server function and 4x 1 / 2.5 / 10Gbps Hyperion 500 interfaces

Właściwości i korzyści
- Industrial switch in a modular system with housing: chassis for RACK 19 "1U cabinet with 8 slots, enabling the installation of hot swap modules
- The modular system allows various configurations of modules, which can have up to 32x 10/100 / 1000M RJ45 or SFP and up to 4x 100M / 1G / 2.5G / 10Gb / s SFP + in a 19 "RACK housing
- ITU-T G.8032 ERPS support, connection reconfiguration in <20ms
- Protocol support: STP, RSTP and MSTP
- IEEE802.1x, Radius, Tacacs + - AAA authentication
- Internal synchronization of the switch with a GPS signal after retrofitting with the H500M-GPS module
- Standard IEEE 1588-2008v.2 (PTPv2): precise time synchronization protocol, hardware time stamping with profile 1588
- The switch is designed in accordance with the requirements of IEC61850-3, IEEE1613 standards
- PROFINET Conformance Class A
- Secondary overvoltage protection in H500M-TRX.1 modules on RJ-45, ITU-T K.44 4kV 10 / 700us ports
- DDMI - SFP modules monitoring function
- Reflectometer test for used pairs in a UTP cable
- Manage IPv4, IPv6, WWW, telnet, SSH and local console CLI, SNMP v1 / v2c / v3
- Working temperature: -40 to + 85 ° C under the right conditions
- Modules for redundant power supply 80-360 V DC, 75-270 V AC or 45 - 60 V DC
Optional functions
- After retrofitting with the H500M-DMC module - security is guaranteed by IEEE 802.1ae MACsec - encryption and data integrity
- Optionally, the device can be retrofitted with the H500M-RBX module for lossless redundancy supporting IEC62439-3 Clause 4.5 HSR / PRP protocols
Optional features included with the license
- Extension with the IEEE 1588-2008v.2 (PTPv2) Power Profile protocol; real-time synchronization for applications in accordance with the IEEE C37.238-2011, C37.238-2017 standards; IEC61850-9-3
- Activation of the Synchronous Ethernet function G.8261
Catalog card

Modular Managed Industrial Ethernet Switch Hyperion 500
Product card
Haven’t found the answer to your bothering questions?

CUS - central management module
Properties and Benefits
- Central management module - a module used in the advanced HYPERION-500 switch with high performance, supporting up to 32 interfaces
- High-performance CPU for managing the system of modules and Chassis
- Uplink interface: 2x or 4x SFP + slots (1G / 2.5G / 10Gb / s) depending on the module version
- Local RJ45 Ethernet port for management
- Supports Synchronous Ethernet support
- Supports IEEE 1588-2008 v2 PTP support
- The structure was designed in accordance with the requirements of IEC61850-3, IEEE1613 standards
PSU - power supply module
Properties and Benefits
- Power supply module for powering various housing versions and installed modules
- Voltage range: 45 - 60V DC or 80-360V DC, 75-270VAC
- Power up to 75W for AC or DC power
- Connector: Terminal Block
- Reverse polarity protection
- The structure was designed in accordance with the requirements of IEC61850-3, IEEE1613 standards



TRX - Transceiver module 4 / 8x UTP or 8x SFP
Properties and Benefits
- Transceiver module with UTP RJ45 ports or with SFP slots
- SFP DDMI: Monitoring of cartridge parameters for all SFP slots
- Support for SFP fiber inserts from any vendors
- Secondary overvoltage protection in TRX.1 modules on RJ-45 ports, ITU-T K.44 4kV 10 / 700us
- Reflectometer test for used pairs in the cable
- Supports Synchronous Ethernet support
- Supports IEEE 1588-2008 v2 PTP support
- The structure was designed in accordance with the requirements of IEC61850-3, IEEE1613 standards
DMC - Dual media converter module
Properties and Benefits
- 1x SFP 100 / 1000Mbit / s slot + 2x UTP RJ45 10/100 / 1000Mbit / s port with each converter
- Two media converters in one module
- Independent management by own IPv4, IPv6 address using HTTP / HTTPS, Telnet, SSH and SNMP v1 / v2c / v3
- Security is ensured by the IEEE 802.1AE MACsec protocol - encryption and data integrity
- Supports Synchronous Ethernet support
- Supports IEEE 1588-2008 v2 PTP support
- The structure was designed in accordance with the requirements of IEC61850-3, IEEE1613 standards.


GPS - GPS receiver module for clock synchronization
Properties and Benefits
- Antenna input with support for active antennas with SMA connector
- 72-channel receiver cooperating with GPS, GLONASS, BeiDou, Galileo systems
- Internal synchronization with the GPS signal of the Hyperion-500 switch
Optional functions
- OCXO on-board generators of various stability or RUBID
Optional features included with the license
- Signal Input / Output 1PPS (One Pulse Per Second)
- 10Mhz clock signal input / output
- ToD (Time-of-Day) signal input / output
- Synchronization signal output E1 G.703, G.704
- Wyjście portu Ethernet (RJ45) z obsługą protokołu IEEE 1588v2 Precision Time Protocol wraz z profilami energetycznymi IEEE/IEC 61850-9-3 oraz IEEE C37.238 oraz SyncE, ITU-T G.8261, ITU-T G.8262 oraz ITU-T G.8264
RBX - REDBOX module
Properties and Benefits
- Available interfaces: 2x SFP slot (100 / 1000Mbps) - HSR / PRP ports or interfaces 2x internal PRP Ethernet ports for communication via switch
- 1x internal Legacy Ethernet port
- IEC 62439-3 Clause 4 support
- IEC 62439-3 Clause 5 support
- The structure was designed in accordance with the requirements of IEC61850-3, IEEE1613 standards
- Full IEEE1588-2008 PTPv2 support for the PRP and HSR protocol in the selected module version


RBMC - REDBOX module with MACsec for encrypted lossless transmission
Właściwości i korzyści
- Available interfaces: 2x SFP slot - HSR / PRP ports or 2x local RJ45 Ethernet ports
- IEC 62439-3 Clause 4 support
- IEC 62439-3 Clause 5 support
- Security is ensured by the IEEE 802.1AE MACsec protocol - encryption and data integrity
- The structure was designed in accordance with the requirements of IEC61850-3, IEEE1613 standards
- Full IEEE1588-2008 PTPv2 support for PRP protocol
General specification of supported standards and protocols
IEEE 802.3 10Base-T Ethernet |
IEEE 802.3u 100Base-TX Fast Ethernet |
IEEE 802.3u 100Base-FX Fast Ethernet Fiber |
IEEE 802.3 10Base-T Ethernet |
IEEE 802.3u 100Base-TX, 100Base-FX Fast Ethernet |
IEEE 802.3ab 1000Base-T |
IEEE 802.3z Gigabit Fiber |
IEEE 802.3ae 10GBASE-SR/LR/ER/ZR (SFP+) 10 Gigabit Ethernet |
IEEE 802.3x Flow Control and Back-pressure |
IEEE 802.1p Class of Service (CoS) |
IEEE 802.1Q VLAN, up to 4095 active VLANs |
IEEE 802.1ad QinQ |
IEEE 802.3ad Link Aggregation Protocol (LACP) |
IEEE 802.1AB Link Layer Discovery Protocol (LLDP) |
IEEE 802.1ak Multiple Registration Protocol (MRP, GARP, GVRP) |
IEEE 802.3az Energy Efficient Ethernet |
Network redundancy
IEEE 802.1D Spanning Tree Protocol (STP) |
IEEE 802.1D-2004 Rapid Spanning Tree Protocol(RSTP) |
IEEE 802.1s Multiple Spanning Tree Protocol (MSTP) |
ITU-T G.8032 v2 Ethernet Ring Protection Switching, Major Ring, Sub Ring – DHP dual homing protection |
ITU-T G.8031 Ethernet Linear Protection Switching 1+1, 1:1 |
Each of the redundancy protocols listed above is available on all ports and on all modules except the management port on the CUS module |
Support via an additional Redbox module – IEC 62439-3 Clause 4, 5 HSR / PRP |
Network security
IEEE 802.1x Port Based Network Access Protocol, EAP, TACACS +, RADIUS – Authentication, Authorization and Accounting – AAA |
IEEE 802.1ae MAC security (MACsec) – data encryption and integrity using the DMC module |
Network synchronization
The device is equipped with an on-board TCXO generator |
Optionally, it can be equipped with an OCXO on-board generator with the following parameters:
|
IEEE 1588-2008 v2 PTP – standard support for synchronization with the profile 1588
|
Optional synchronization with Power Profile IEEEC37.238-2011, IEEEC37.238-2017 |
Optional also Synchronous Ethernet, G.8261: (Timing and synchronization aspects in packet networks) |
Ethernet interface
Ethernet connectors in 19 “RACK 1U housing: Store and forward operating mode, up to 32x RJ45 (10/100 / 1000M) or SFP (100 / 1000M) ports in 19” RACK housing, Jumbo frame: 9600 B, packet buffer size: 4 MB, Backplane (Switching capacity): 160 Gbps, Forwarding: 54 Mpps |
Mac array: 32k |
VLAN: 4094 VLAN entries, 802.1Q, 802.1QinQ, Private VLAN, VLAN translation |
QoS: Support 8 physical queues, Weighted Round Robin algorithm and Strict Priority Queuing. Priority settings based on: PCP 802.1p, DSCP / ToS priorities, port priority settings, the ability to configure priorities based on TCP / UDP port numbers |
Flow Control: Flow Control – controls sent and received packets to prevent buffer overflow, i.e. data loss |
Storm protection: filtering for inbound traffic of Broadcast, Multicast, Unknown DA or all packets, filtering for outgoing traffic for all types of packets, rate limiting |
IGMP snooping V1 / V2 / V3, IGMP Filtering / Throttling, IGMP query, IGMP proxy reporting, MLD snooping V1 / V2 |
Port Mirroring: Copy network traffic to a specific port, Monitor traffic on selected ports |
Port Trunk: IEEE 802.3ad LACP or Static Aggregation |
Loop Protection Port |
RMON, MIB II, DNS, NTP |
IEEE802.1ab LLDP, LLDP-MED |
SFP DDMI: Digital Diagnostic Monitoring for all SFP slots |
IEEE 802.3az: Energy Efficient Ethernet, energy reduction, 4 modes |
OTDR test in the UTP module: Each RJ45 port can perform a OTDR test of all pairs (4 pairs for 1000Base-T and 2 pairs for 10 / 100Base-Tx) for a twisted pair cable, i.e. short circuit or break in pairs diagnostics and the total length of the cable up to next active device |
ITU K.44 – secondary, 4kV, 10 / 700us overvoltage protection built in TRX.1 modules on RJ-45 ports as required: Resistibility tests for telecommunication equipment exposed to overvoltages and overcurrents – Basic Recommendation |
Management
IPv4, IPv6, ARP, ICMP, TCP, UDP, DNS |
DHCP Client, Server, Relay Option 82 |
The processor has up to 10 interfaces with different IP addresses, separated by a VLAN |
Access permission: password, source IP configurable range |
Access level configuration – read / write, independently configured for many users |
HTTP, HTTPS – the device has a self-signed certificate installed, but it is possible to install another certificate |
Telnet, SSH, NTP, TFTP, Syslog – cooperation with the syslog server |
SNMP v1 / v2c / v3, SNMP trap, inform |
Local (Ethernet / RS-232) and Remote CLI |
System event and alarm log |
MIB II |
Work environment requirements
Working temperature: -40 to + 85 ° C with a minimum air flow of 0.4 m / s. |
Working temperature: -40 to + 70 ° C with a minimum air flow of 0.0m / s |
The working time at the maximum temperature of + 85 ° C is up to 16 hours |
Standard operating ambient humidity: 5% -95% |
Supported standards, recommendations and EMC and safety directives
PN-EN 55011:2012 |
PN-EN 55022:2010/AC:2011 |
PN-EN 55024:2011/A1:2015-08 |
PN-EN 60950-1:2007/A2:2014-05 |
EMC 2004/108/WE |
LVD 2006/95/WE |
PN-EN 60825-1:2014-11 |
IEC 61000-4-2 |
IEC 61000-4-3 |
IEC 61000-4-4 |
IEC 61000-4-5 |
IEC 61000-4-6 |
IEC 61000-4-8 |
IEC 61000-4-11 |
IEC 61000-4-12 |
IEC 61000-4-29 |
IEC 61850-3 |
IEEE 1613-2009 |
More information can be found in the product catalog