Managed industrial Ethernet switch with PTPv2 time synchronization server function and 4x 1/2,5/10 Gbps i 8/16x 10M/100M/1G RJ45 PoE÷High PoE IEEE802.3bt lub 8/16x 100M/1G SFP
Industrial managed Ethernet switch equipped with 4x 1/2.5/10 Gbps and 8/16x 10M/100M/1G RJ45 PoE÷High PoE IEEE802.3bt ++ or 8/16x 100M/1G SFP interfaces

Properties and Benefits
- A family of industrial switches featuring 4x 10/2.5/1Gbps SFP/SFP+ slots and 8/16x 10M/100M/1Gbps RJ45 ports or 100M/1Gbps SFP slots
- Additional NMI UTP RJ45 10 / 100Mbit / s management port
- ITU-T G.8032 ERPS support, connection reconfiguration in <20ms, up to 64 rings simultaneously
- Support for STP, RSTP and MSTP protocols
- IEEE802.1x authentication, Radius, Tacacs+ - AAA
- Support for PRP (IEC 62439-3 Clause 4) or HSR (IEC 62439-3 Clause 5) on ports in the R module.
- The following IEEE1588 v.2 (PTPv.2)-based precision time synchronization profiles are available in the HYPERION-200.2 hardware-supported version: 1588 default, G.8265.1 and G.8275.1
- NTP protocol in server/client mode and SNTP
- Switch designed in accordance with the requirements of IEC61850-3, IEEE1613 standards for substations
- As standard, secondary surge protection in UTP modules on RJ-45 ports only in the transmission path, ITU-T K.44 4kV 10/700us
- Management IPv4, IPv6, Web, telnet, SSH and local CLI (RS232), SNMP v1,2,3
- Access security SNMPv3, HTTPS, SSH
- DDMI - SFP module monitoring function
- Energy Saving with Energy Efficient Ethernet (EEE).
- Ethernet OAM support (Link OAM and Service OAM)
- Standard equipped with I/O interfaces: interface 4 inputs and 2 outputs 'cc' for monitoring, alarms and control purposes
- Operating temperature: -40 to +85°C when conditions are met
- Rugged metal housing for mounting on a DIN rail
- Power supply 36-60 VDC or 80-360 VDC / 75-270 V AC
Optional features
- L3 routing support - static routing
- PoE ÷ PoE ++ support up to 90W per UTP port (on all ports max. 500W), Watchdog PoE
Optional features included with the license
- Extension with the IEEE 1588-2008v.2 (PTPv2) Power Profile protocol; real-time synchronization for energy applications in accordance with IEEE C37.238-2011, C37.238-2017 standards; IEC61850-9-3,
- Activation of the Synchronous Ethernet function G.8261
Application
Thanks to its reliability, Hyperion 200 is used in industries such as:

Energetics

CCTV

Fuel industry
Catalog card

Ethernet Switch Hyperion-200
Product card
Haven’t found the answer to your bothering questions?
Supported transmission standards
IEEE 802.3 10Base-T Ethernet |
IEEE 802.3u 100Base-TX Fast Ethernet |
IEEE 802.3u 100Base-FX Fast Ethernet Fiber |
IEEE 802.3ab 1000Base-T Gigabit Ethernet |
IEEE 802.3ae 10GBASE-SR / LR / ER / ZR (SFP +) 10 Gigabit Ethernet |
IEEE 802.3z Gigabit Fiber |
IEEE 802.3x Flow Control and Back-pressure |
IEEE 802.1AB Link Layer Discovery Protocol (LLDP) |
IEEE 802.30ah Link OAM |
IEEE 802.1p Class of Service (CoS) |
IEEE 802.1Q VLAN |
IEEE 802.1ad QinQ |
IEEE 802.1d – Spanning Tree Protocol (STP) |
IEEE 802.1w – Rapid Spanning Tree Protocol (RSTP) |
IEEE 802.1s – Multiple Spanning Tree Protocol (MSTP) |
IEEE 802.3ad Link Aggregation Protocol (LACP) |
IEEE 802.1ak Multiple Registration Protocol (MRP, GARP, GVRP) |
IEEE 802.1x Port Based Network Access Protocol, EAP, TACACS+, RADIUS – authentication, authorization and accounting functions – AAA |
IEEE 802.3az EEE |
IEEE 802.3af/at type 1/2 and PoE+ up to 30W per port, maximum on all ports 500W |
IEEE 802.3bt High PoE up to 90W per port, 500W maximum on all ports |
ITU K.44 – built-in secondary overvoltage protection on RJ-45 for transmission path, 4kV, 10/700us compliant: Resistibility tests for telecommunication equipment exposed to overvoltages and overcurrents – Basic Recommendatio n |
Supported protocols
IPv4, IPv6, ARP, ICMP, TCP, UDP, DNS |
IGMP v1, v2, v3, MLD v1, v2, GMRP, GVRP, |
SNMP v1/v2c/v3, |
DHCP client/server, |
NTP client/server, SNTP, |
IEEE1588 PTP v2 (available only version 200.2), |
Synchronous Ethernet (only available on version 200.2) |
HTTP, HTTPS, Telnet, SSH v2, Syslog, |
EtherNet/IP, SNMP Inform, RMON, LLDP, LLDP-MED |
MIB-II, Ethernet-Like MIB PROFINET Conformance Class A |
IEEE 802.1x Port Based Network Access Protocol, EAP, TACACS+, RADIUS, NAS |
Supported standards, recommendations and directives EMC, safety *
PN-EN 55024:2011 |
PN-EN 60825-1:2014-11 |
PN-EN IEC 62368-1:2020-11 |
EMC 2014/30/EU |
LVD 2014/35/EU |
IEC 61850-3:2014 |
IEEE 1613-2009 |
IEC 61000-4-2 |
IEC 61000-4-3 |
IEC 61000-4-4 |
IEC 61000-4-5 |
IEC 61000-4-6 |
IEC 61000-4-8 |
IEC 61000-4-11 |
IEC 61000-4-12 |
IEC 61000-4-29 |
Ethernet interfaces
Ethernet Connectors: 4 x 1G/2.5G/10Gbps SFP+, 8/16x 10/100/1000Mbps RJ45 ports or 8/16x 100M/1000M SFP slots (100Mbps speed on Optical Interface only works with optical SFP inserts) |
Non-blocking switching matrix: 160Gbps |
Forwarding: 84-72 Mpps depending on the number of ports |
QoS: Support for 8 physical queues, Weighted Round Robin algorithm and Strict Priority queuing. Priority settings based on: 802.1p PCP priorities, DSCP/ToS, port-based priority settings, TCP/UDP port number-based priority configuration capabilities |
VLANS: 4094 VLAN entries, 802.1Q, 802.1QinQ, private VLANs, VLAN translation. |
Flow Control: Flow Control – controls the sent and received packets to prevent buffer overflow, i.e. data loss |
Storm protection: filtering for incoming traffic of Broadcast, Multicast, Unknown DA or all packets, outgoing traffic filtering for packets of all types, bandwidth limiting |
Security: HTTP/HTTPS, SSL/SSH, IEEE 802.1x Port Based Network Access Protocol, EAP, TACACS+; RADIUS authentication, authorization and accounting functions – AAA |
IGMP snooping: V1/V2/V3, IGMP Filtering/Throttling, IGMP query, IGMP proxy reporting, MLD snooping V1/V2 |
Syslog – cooperation with the syslog server, |
Port Mirroring: monitoring or analyzing traffic on selected ports |
IEEE 802.3az: Energy Efficient Ethernet, reduced power consumption, 4 modes |
Port Trunk: IEEE 802.3ad LACP or static aggregation |
RMON, MIB II, Port mirroring, DNS, IEEE802.1ab LLDP, LLDP-MED |
MAC address table: up to 32k entries |
Network redundancy
|
Optional L3 – static routing |
ITU K.44 – built in TRX.1 modules on RJ-45 ports only in the transmission path secondary, 4kV, 10 / 700us overvoltage protections in accordance with the requirements of: “Resistibility tests for telecommunication equipment exposed to overvoltages and overcurrents – Basic Recommendation” |
I/O interface - inputs
Number of inputs – 4 |
Input type – digital, potential-free |
Connector: screw |
I/O interface - outputs
Number of outputs – 2 |
Type of outputs – relay NO / NC |
Maximum switching current – 0.5A 60VDC with resistive load |
Connector: screw |
Device start-up time
Full operability after a cold start after a maximum of 30 seconds. |
MTBF
Time: 650,000 hours |
Standard: Telecordia, SR-332 |
Management
SNMP v1 / 2c / 3, SSH |
HTTP / HTTPS protocol – management via a web browser |
SSH v2, TELNET |
Local CLI console (RS-232) |
“Privilege level” – permission level configuration – read / write, independently configured for many users |
REDBOX module
Module that enables lossless network redundancy |
2x SFP slots – including 2x HSR/PRP ports supporting HSR (High-availability Seamless Redundancy) / PRP (Parallel Redundancy Protocol) for network redundancy and 1x RJ45 Ethernet Legacy port |
Support IEC 62439-3 Clause 4 |
Support IEC 62439-3 Clause 5 |
Supports IEEE 1588v2 PTP ( only available on 200.2) |
Transparency for transmission in PRP mode |
Network synchronization
The device is equipped with an on-board TCXO generator |
IEEE 1588-2008 v2 PTP – standard support for synchronization with the profile 1588
|
Optional synchronization with Power Profile IEEEC37.238-2011, IEEEC37.238-2017 |
Optional also Synchronous Ethernet, G.8261: (Timing and synchronization aspects in packet networks) |
Time synchronization I/O interface module
Signal Input / Output 1PPS (One Pulse Per Second) |
10Mhz clock signal input / output |
ToD (Time-of-Day) input / output – the output can be reconfigured into an IRIG-B signal |
Power
DC 36-60V power supply |
DC80-360V power supply; AC 75-270V |
Optional two DC power inputs – redundant |
Screw connection for AC or DC power |
Total power consumption (without PoE ports) <40W |
PoE power supply
Compliant with IEEE802.3af, IEEE802.3at |
Power available for each port up to 90W |
For 55VDC power supply, the maximum total PoE power is 500W |
Physical features
Dimensions [141 mm or 183x135x120] mm |
Weight up to 2.5 kg |
Mounting DIN rail or free-standing |
Metal housing |
Work environment requirements
Working temperature: -40 to + 85 ° C with a minimum air flow of 0.4 m / s |
Working temperature: -40 to + 70 ° C with a minimum air flow of 0.0m / s |
The working time at the maximum temperature of + 85 ° C is up to 16 hours |
Standard operating ambient humidity: 0 to 95% (non-condensing) |
Location type: class C in accordance with PN-EN 60870-2-2 – sheltered locations |
Protection class in accordance with IP-30 |
More information can be found in the product catalog